Products
PTFE Diaphragm

PTFE Diaphragm

Model:PTFE Diaphragm
PTFE diaphragms for metering, diaphragm and AODD pumps and diaphragm valves: solid PTFE or PTFE film bonded to EPDM or NBR, moulded or skived to drawing, one side etched for bonding, service from -180 °C to +260 °C.

PTFE Diaphragm: Pump and Valve Membranes for Chemical Duty

A PTFE diaphragm is the membrane that separates the process fluid from the actuator in a metering pump, a diaphragm pump or a diaphragm valve. It has to be inert to the fluid, flexible enough to stroke millions of times, and thin enough not to steal displacement from the pump. Kaxite moulds and skives these diaphragms to drawing, in solid PTFE or as a PTFE film bonded to an elastomer backing, with one face etched for bonding.

  • 2.15 g/cm³ apparent density
  • ≥30 MPa tensile strength
  • ≥300 % elongation
  • −180 to +260 °C material service
Duty cycle

One stroke, four moments

01SuctionThe diaphragm retracts, the inlet opens and the chamber fills.
02CompressionThe actuator pushes and the diaphragm folds at the convolution.
03DischargeThe outlet opens and the fluid leaves at line pressure.
04ReturnThe diaphragm relaxes; its memory sets how repeatable the dose is.

That cycle is why a diaphragm is specified as a fatigue part, not as a gasket. A gasket is compressed once and stays put; a diaphragm bends at the same radius twice per stroke, several million times a year, in contact with the fluid on one side and the actuator on the other. Almost every premature failure is a fatigue or installation problem rather than a chemical one.

Construction

Solid PTFE, or PTFE on an elastomer backing

A solid PTFE diaphragm gives the cleanest wetted path: nothing but PTFE touches the fluid, and there is no elastomer to swell, extract or age. The cost is flex life. PTFE fatigues faster than an elastomer, so a solid diaphragm is normally thin, short-stroke, and reserved for small metering duty, high-purity chemical dosing and analytical instruments where contamination is the governing risk.

A PTFE-faced diaphragm splits the job. A skived PTFE film is bonded to an EPDM or NBR backing: the elastomer carries the flexing and the PTFE provides the wetted face. This is the standard construction for air-operated double-diaphragm pumps and larger metering pumps, because it survives far more strokes at the same pressure. The PTFE film itself comes from the same skived PTFE film used elsewhere in our range, and the backing is normally cut from an elastomer sheet selected for the media.

The bond is where these parts are usually lost. One face of the PTFE is etched so the adhesive can key to it, the backing is prepared to match, and the assembly is cured under pressure. A diaphragm that delaminates in service was almost always bonded onto a contaminated or under-etched surface, or run above the temperature the adhesive was rated for.

✓ Do

  • Match the backing elastomer to the media, not only the PTFE face.
  • Quote the stroke length and pressure, not only the outline dimensions.
  • Keep the bead and convolution radius as drawn — they set the flex life.
  • Ask for an etched face if you will bond the diaphragm in your own plant.

✕ Don't

  • Run a solid PTFE diaphragm beyond the stroke it was designed for.
  • Over-torque the flange to stop a weep; it extrudes the bead.
  • Fit a diaphragm that has been stored folded or creased.
  • Treat the diaphragm as a static gasket — it is a moving part.
Failure map

How these diaphragms actually fail

Table 1 — Failure modes and what they point to
Failure What it looks like Usual cause Severity
Flex crack at the convolution Fine radial crack at the fold Stroke longer than design, radius too tight, over-pressure ●●●
Bead extrusion Flattened or squeezed edge Over-torqued flange, wrong bead profile ●●○
Delamination or blistering PTFE face lifting or bubbling Contaminated or under-etched bond, over-temperature ●●●
Backing swell or softening Rubber soft, dimensions changed Media attacks the EPDM or NBR backing ●●●
Abrasive thinning Polished or scored wetted face Solids in the media ●●○
Compression set Short stroke, drifting dose Sustained pressure at temperature ●●○

Reading the failed part is the fastest way to specify the replacement. A crack at the fold says the stroke or the radius is wrong, not the material. A clean PTFE face with a swollen backing says the backing elastomer was the wrong choice. A face lifting at the edge says the bond was never good enough, and a new diaphragm of the same construction will fail the same way.

Selection

Which construction for which duty

Table 2 — Typical construction by application
Duty Typical construction Why
Metering and dosing pump PTFE-faced EPDM, or solid PTFE for short stroke Chemical resistance with dose repeatability
Air-operated double diaphragm pump PTFE film on EPDM or NBR Flex life at long stroke and higher pressure
Diaphragm valve PTFE-faced or solid PTFE Inert wetted face with a short stroke
Compressor and vacuum duty Solid or filled PTFE Temperature range and dry running
Food and pharmaceutical Virgin PTFE, documented Low extractables and audit paperwork

If the pump is handling a fluid that attacks the backing but not PTFE, the answer is usually a solid diaphragm with a shorter stroke rather than a different elastomer. If the pump is handling a fluid that attacks neither, the faced construction will simply last longer and cost less per thousand litres pumped.

Ordering

What to send

  • Pump or valve model, or the old diaphragm as a sample.
  • Outside diameter, bore, bead profile and bolt pattern.
  • Stroke length and working pressure — the two numbers that decide the construction.
  • Media, concentration and temperature, including cleaning cycles.
  • Backing elastomer if you have a preference, and whether one face must be etched.
  • Quantity, and whether the part is for a trial or a production schedule.

A photograph with a ruler is enough for a first opinion; a sample is better, because a used diaphragm shows where it was bending. Prototypes and one-off replacements are normal work, and they run through the same Ningbo workshop as production. Send the details through the inquiry form and technical sales replies within 2 business hours.

FAQ

Questions buyers ask before the first order

What is a PTFE diaphragm made of?
It is made from PTFE suspension resin with high strength and toughness, either moulded to shape or skived from a PTFE billet and finished. In most pump duty the PTFE is a thin film bonded to an EPDM or NBR backing, with one side of the PTFE etched so the adhesive can key to it.
Why not use solid PTFE diaphragms everywhere?
Because flex life, not chemical resistance, is the limit. Solid PTFE resists almost every process fluid but fatigues faster than an elastomer, so it is used thin, at short stroke, and where nothing but PTFE may touch the fluid. For long-stroke air-operated pumps a PTFE-faced elastomer diaphragm survives far more cycles.
What temperature and pressure can a PTFE diaphragm take?
The PTFE itself runs from −180 °C to +260 °C, but the real limit is usually the backing elastomer and the adhesive, which are rated lower. Pressure depends on diameter, stroke and how the bead is supported. Give us the pump model and duty point and we will confirm the construction rather than quote one blanket rating.
Are PTFE diaphragms suitable for food and pharmaceutical duty?
Virgin PTFE is widely used in both, but suitability depends on the grade, the backing and the paperwork. Tell us the standard your audit applies and we will confirm which construction and which documentation we can supply.
How do I identify the right diaphragm size?
Send the pump or valve model, or the old diaphragm. We measure the outside diameter, the bore, the bead profile and the bolt pattern, and match the stroke and pressure to the duty. A photograph with a ruler is enough for a first check.
What usually causes a PTFE diaphragm to fail?
A radial flex crack at the convolution, usually from a stroke longer than the diaphragm was designed for. The next most common are bead extrusion from over-torquing the flange, delamination from a contaminated or under-etched bond, and swelling of the elastomer backing in a medium it was not chosen for.

Send the pump model or the failed diaphragm

We will read the failure, confirm the construction and quote against the duty point.

Send Inquiry
Contact Info

Request a Quote or Technical Consultation

Share your sealing requirement and our technical sales team will respond within 24 business hours. For fastest service, include your flange specification, operating pressure, temperature, and process media in the message below.

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept