Products
Ceramic Fiber Tape

Ceramic Fiber Tape

Model:KXT CF104
KXT CF104 is a ceramic fiber woven tape rated for continuous service from 650 °C to 1260 °C, available in two reinforced constructions. CF104-I is reinforced with a metallic wire (Inconel or stainless steel) to hold the woven structure under vibration and thermal cycling. CF104-AI combines aluminum foil with metal wire reinforcement for reflective heat shielding — an established asbestos tape replacement for cable wrap, pipe wrapping, and fireproofing. Standard packaging: 30 m/roll in 20 kg plastic woven bag or 20 kg carton. Send your application, temperature, and required width for a same-week factory quote.

Ceramic Fiber Tape for Cable Wrap, Pipe Wrap and Fireproofing — 650 °C to 1260 °C

KXT CF104 is a **ceramic fiber woven tape** for continuous service from **650 °C to 1260 °C**. It is supplied in two **reinforced constructions** — one built for **mechanical hold under vibration and thermal cycling**, the other built for **reflective heat shielding and asbestos replacement**. Where plain ceramic fiber tape degrades at the edge under repeated movement, the metallic wire in CF104-I keeps the weave edge intact; and where a bare white surface is not enough for fireproofing or reflective insulation, the aluminum foil in CF104-AI delivers. For the wider material family, see Ceramic Fiber.

Temperature Envelope — Where the Tape Actually Operates

Continuous Service Range: 650 °C – 1260 °C Rated ceiling set by the ceramic fiber — reinforcements extend performance within the envelope
650 °C ~800 °C ~1000 °C 1260 °C
650 °C — Lower Band Typical low-end service: continuous insulation, general cable wrap. Wire reinforcement holds shape at the lower band without stress from thermal expansion.
800–1000 °C — Working Band The bulk of CF104-I cable and pipe wrap applications. Wire reinforcement carries the woven structure through repeated thermal cycling in this band.
1000–1260 °C — Upper Band Reserved for CF104-AI fireproofing and high-temperature insulation where the aluminum foil adds reflective shielding. Confirm the exact upper limit against your service condition.

CF104-I vs CF104-AI — Which One Do You Need?

Variant A · CF104-I

Ceramic Fiber Tape with Metallic Wire

The plain ceramic fiber tape reinforced with a metallic wire (Inconel or stainless steel). The wire is woven into the tape so the structure does not unravel at the edge under vibration or repeated thermal expansion — the failure mode that shortens the life of unreinforced woven ceramic tape.

Inconel wireStainless steel wireWoven-in reinforcement
Choose when: you need high-temperature electrical cable and wire covering, or pipe wrapping where the tape will be subject to vibration, thermal cycling, or mechanical flex.
Variant B · CF104-AI

Ceramic Fiber Tape with Aluminum Foil + Wire

The same wire-reinforced ceramic fiber tape, faced with aluminum foil. The foil adds reflective heat shielding and makes the tape a direct substitute for asbestos tape in thermal insulation work — plus fireproofing and fire-barrier applications where the bare white surface would not perform.

Aluminum foil facingMetal wire baseReflective shielding
Choose when: you are replacing asbestos tape, you need reflective heat shielding or fireproofing, or the surface needs an aluminum facing for thermal reflection.

What the Reinforcement Actually Does — Layer by Layer

CF104-I — Woven Ceramic Fiber + Wire The ceramic fiber provides the high-temperature insulation. The metallic wire — Inconel for the highest service, stainless steel for standard duty — is woven through the structure so the tape holds its shape under vibration and thermal cycling. Without the wire, an unreinforced ceramic tape edge frays in service.
CF104-AI — Woven + Wire + Aluminum Foil Adds a layer of aluminum foil on top of the wire-reinforced ceramic fiber base. The foil reflects radiant heat and makes the tape visually identifiable in fireproofing work. This is the construction that replaces asbestos tape in thermal insulation — same function, no asbestos content.

Four Application Quadrants — Where CF104 Is Specified

Q1
High-Temperature Cable & Wire Covering Electrical cable and wire wrapping where the tape must survive service temperatures that would melt conventional insulation tape. CF104-I is the standard choice for cable and wire covering.
Q2
Pipe Wrapping & Thermal Insulation Pipe wrap for thermal and mechanical protection at elevated temperature. CF104-I for the primary wrap; CF104-AI where reflective shielding is also required. See Ceramic Fiber for the wider insulation range.
Q3
Asbestos Tape Replacement CF104-AI is specifically positioned as an asbestos tape substitute for thermal insulation. Same high-temperature insulation function, without the asbestos content. See Dust-Free Asbestos for the comparison materials.
Q4
Fireproofing & Fire Barriers Fireproofing work where reflective shielding and non-combustible construction are required. CF104-AI is the specification grade for fireproofing and fire-barrier applications.

Packaging and Shipping

30 m Standard roll length
20 kg Net per plastic woven bag
20 kg Net per carton

Procurement FAQ

What is the temperature range of ceramic fiber tape CF104?

Both CF104-I and CF104-AI are rated for continuous service from 650 °C to 1260 °C. The rated ceiling is determined by the ceramic fiber itself. The metallic wire in CF104-I and the aluminum foil in CF104-AI extend mechanical and reflective performance within that temperature envelope rather than raising it.

What is the difference between CF104-I and CF104-AI?

CF104-I is wire-reinforced — Inconel or stainless steel wire woven into the ceramic fiber structure for hold under vibration and thermal cycling. CF104-AI is the same wire-reinforced base with aluminum foil facing for reflective shielding, fireproofing, and asbestos tape replacement. Both share the same 650–1260 °C envelope.

Can ceramic fiber tape replace asbestos tape?

Yes. CF104-AI is specifically positioned as an asbestos tape substitute for thermal insulation work — same function without asbestos content. For projects transitioning from asbestos, send your existing tape specification (width, thickness, temperature rating) and we will confirm the equivalent CF104 configuration. See Dust-Free Asbestos for the material family.

What are the typical applications?

High-temperature electrical cable and wire covering, pipe wrapping for thermal and mechanical protection, fireproofing, and asbestos tape replacement. CF104-I is preferred for cable and pipe wrap where vibration and thermal cycling stress the tape; CF104-AI is preferred for reflective heat shielding, fireproofing, and asbestos replacement. See Ceramic Fiber for the full range of ceramic fiber formats.

What is the roll length and packaging?

Standard roll length 30 m. Packaging is 20 kg net in a plastic woven bag or 20 kg net in a carton. Mixed-variant pallet loading (part CF104-I, part CF104-AI) is available — submit your project split for a loading plan. Related formats include Ceramic Fiber Cloth for wider woven goods and Ceramic Fiber Rope for braided sealing.

Need a ceramic fiber tape quote or a variant recommendation? Tell us your application (cable, pipe, fireproofing, or asbestos replacement), operating temperature, required width, and quantity — our technical sales team responds within 2 business hours with a CF104-I / CF104-AI recommendation and factory quote.
Request Factory Quote
Send Inquiry
Contact Info

Request a Quote or Technical Consultation

Share your sealing requirement and our technical sales team will respond within 24 business hours. For fastest service, include your flange specification, operating pressure, temperature, and process media in the message below.

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept