Products
Type D Flange Insulation Gasket Kit

Type D Flange Insulation Gasket Kit

Model:KXT-1001
Type D Flange Insulation Gasket Kit are used for controlling losses due to corrosion. They can be used to control stray electric currents in piping at oil, gas, water, refinery, and chemical plants, to increase the effectiveness of cathodic protection systems.
Rating: 5.0
(Rating Count: 1)

KXT-1001 Type D Flange Insulation Gasket Kit is designed specifically for Ring‑Type Joint (RTJ) flanges requiring electrical isolation. Manufactured from medium‑weave fabric‑reinforced phenolic, this RTJ insulation gasket prevents galvanic corrosion, stray current interference, and electrolytic degradation in oil, gas, water, refinery, and chemical plant piping systems. Available in octagonal (standard) and oval (on request) shapes. Complete kit includes the insulating gasket, phenolic sleeves, and stainless steel washers. Request a quote →

KXT-1001 Type D Flange Insulation Gasket Kit – RTJ Isolation

KXT-1001 Type D Flange Insulation Gasket Kit – RTJ Electrical Isolation Solution

The KXT-1001 Type D Flange Insulation Gasket Kit provides a reliable electrical barrier for Ring‑Type Joint (RTJ) flanges, effectively preventing galvanic corrosion and stray current damage in critical piping systems. The central gasket is precision‑manufactured from medium‑weave fabric‑reinforced phenolic, offering excellent dielectric strength, mechanical durability, and resistance to a wide range of process media. This RTJ insulation gasket is a direct replacement for standard ring joint gaskets in applications requiring cathodic protection or electrical isolation.

Each kit is supplied complete with the insulating RTJ gasket, phenolic insulating sleeves, and stainless steel washers – all engineered to ASME/ANSI dimensions. Our Type D gaskets are available in standard octagonal shapes, with oval configurations available on request. Contact our technical team for flange specification and custom sizing requirements.

Key Features of Type D RTJ Insulation Gaskets

  • ✅ RTJ Flange Compatible – Specifically designed for ring‑type joint flanges, replacing standard metal ring gaskets.
  • ✅ Superior Electrical Isolation – Medium‑weave fabric‑reinforced phenolic provides high dielectric strength.
  • ✅ Complete Kit – Includes insulating gasket, phenolic sleeves, and stainless steel washers.
  • ✅ Corrosion Prevention – Protects piping systems from galvanic and electrolytic corrosion.
  • ✅ Standardised Dimensions – Manufactured to ASA (ANSI) gasket dimensions for interchangeability.
  • ✅ Shape Options – Octagonal (standard) and oval (available on special request).
  • ✅ Proven in Critical Service – Trusted in oil, gas, water, refinery, and chemical plant applications.
  • ✅ Installation Support – Alignment pins (≥3/32″ larger than bolt size) recommended for proper centering.
Type D RTJ Insulation Gasket – Construction Diagram

Type D RTJ Insulation Gasket – Octagonal profile for ring‑type joint flanges

Technical Specifications – KXT-1001 Type D RTJ Insulation Kit

Parameter Value / Range
Model KXT-1001
Type D – RTJ (Ring‑Type Joint) Insulation Gasket Kit
Gasket Material Medium‑weave fabric‑reinforced phenolic
Shapes Available Octagonal (standard), Oval (on request)
Flange Standards ASME B16.5 / API 6A / ANSI
Kit Components Insulating gasket + Phenolic sleeves + Stainless steel washers
Dielectric Strength ≥ 15 kV/mm (phenolic)
Temperature Range -40°C to +150°C (phenolic)
Pressure Rating 150# to 2500# (matching RTJ flange rating)
Alignment Pins Recommended ≥ 3/32″ (2.38 mm) larger than bolt size
Tape Recommendation Wrap flange exterior after installation to prevent bridging

* Custom dimensions and non‑standard shapes available. Consult our engineering team for specific flange requirements.

Material Options – Choose the Right RTJ Insulation Material

Select the optimal gasket material based on your process media, temperature, and mechanical requirements.

Material Dielectric Strength Max. Temperature Typical Applications
Phenolic (Standard) ≥ 15 kV/mm 150°C General isolation, water, air, mild chemicals
G‑10 (FR‑4) ≥ 20 kV/mm 200°C Higher temperature, higher mechanical strength
G‑7 (Silicone) ≥ 18 kV/mm 250°C High temperature – NOT for hydrocarbons (not even trace amounts)
PTFE ≥ 20 kV/mm 260°C Aggressive chemicals, high‑purity, corrosive media

* G‑7 material should not be used with hydrocarbons, not even trace amounts. Always consult our engineering team for material compatibility.

Installation Guidelines – Best Practices for RTJ Insulation Kits

  • 🔹 Alignment Pins – Always use alignment pins at least 3/32″ (2.38 mm) larger than the bolt diameter to ensure proper centering.
  • 🔹 Flange Surface – Ensure RTJ grooves are clean and free from debris or damage before installation.
  • 🔹 Tape Wrap – Wrap insulating tape around the outside of the flange after installation to prevent foreign material from bridging the isolation gap.
  • 🔹 Bolt Torque – Follow standard RTJ flange torque procedures – do not over‑tighten as phenolic may crack under excessive compression.
  • 🔹 Inspection – Check for proper seating in the RTJ groove before bolting – the gasket should sit uniformly in the groove.
  • 🔹 Re‑use – Type D gaskets are not recommended for re‑use; always install a new kit after flange disassembly.

Typical Applications

Cathodic Protection Systems Isolate pipeline sections in wellheads, compressor stations, and pipeline junctions.
Oil & Gas RTJ Flanges High‑pressure wellhead, manifold, and choke connections requiring electrical isolation.
Refinery & Chemical Plants RTJ flanges in corrosive and electrolytic environments.
Water & Wastewater Isolate RTJ connections in treatment plants and pumping stations.
Offshore & Subsea Corrosion protection for RTJ flanges in seawater and marine environments.
Power Generation Cooling water and steam systems with RTJ flange connections requiring isolation.

Why Choose Kaxite for Type D RTJ Insulation Kits?

ASME / API Compliance – All Type D gaskets are manufactured to ASME B16.5 and API 6A dimensional standards.
Complete Kits – Every kit includes the insulating gasket, phenolic sleeves, and stainless steel washers.
Custom Shapes – Octagonal as standard; oval shapes available on special request.
Material Traceability – Full certification and traceability for all components.
Technical Support – Expert guidance on material selection, installation, and troubleshooting.
Fast Delivery – Standard sizes in stock; custom orders produced within 7‑15 days.

Field Proven: Kaxite Type D RTJ insulation kits are installed in thousands of critical pipeline and wellhead applications worldwide, delivering reliable isolation and corrosion protection.

Quality Assurance & Compliance

All KXT-1001 Type D kits are manufactured under strict quality controls in our ISO 9001:2015 certified facility. Each gasket is inspected for dimensional accuracy, dielectric strength, and surface finish. We can provide EN 10204 3.1/3.2 material certificates, NACE MR0175 compliance, and third‑party inspection reports upon request.

  • ISO 9001:2015
  • ASME B16.5 / API 6A
  • 100% Dimensional Inspection
  • Dielectric Strength Testing
  • Full Material Traceability

Frequently Asked Questions – Type D RTJ Insulation Kits

Q: What is a Type D flange insulation gasket?
A: Type D is the designation for insulation gaskets designed for Ring‑Type Joint (RTJ) flanges. They replace standard metal ring gaskets while providing electrical isolation for cathodic protection and corrosion control.
Q: What shapes are available?
A: Our standard Type D gaskets are supplied in octagonal shape – the most common RTJ profile. Oval shapes are available on special request. Please specify your requirement when ordering.
Q: What is included in a complete kit?
A: Each Type D kit includes the insulating RTJ gasket, phenolic insulating sleeves (to isolate bolts), and stainless steel insulating washers. This provides complete electrical isolation of the entire flange joint.
Q: Can Type D gaskets be re‑used?
A: No – like metal RTJ gaskets, phenolic Type D gaskets are designed for single‑use only. Re‑use is not recommended as the material may have taken a permanent set and sealing performance cannot be guaranteed.
Q: Is tape wrapping really necessary?
A: Yes – we strongly recommend wrapping insulating tape around the outside of the flange after installation. This prevents moisture, dirt, or debris from creating a conductive bridge between the isolated flanges, which would compromise the isolation effectiveness.

Partner with Kaxite Sealing – your trusted supplier of Type D RTJ Flange Insulation Gasket Kits. With ASME/API compliance, a complete range of materials, and a commitment to quality, we deliver isolation solutions that protect your critical RTJ flanged connections from corrosion. Request a free design review or get a bulk quote today – our engineering team responds within 24 hours.

Send Inquiry
Contact Info

Request a Quote or Technical Consultation

Share your sealing requirement and our technical sales team will respond within 24 business hours. For fastest service, include your flange specification, operating pressure, temperature, and process media in the message below.

Rating:
5.0
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept